FONYINDA-COLUMN-010

FONYINDA-COLUMN-010

Model No.: ENC-ACL007A

place of origin: China

Types of: Wall Charger, Charging Stand

Certification: Weee, Ul, Sig(bluetoothsig), Sgs, Rohs, Rech, Gs, Fcc, Csa, Ce, Bis(isi)

use: Electric Car, Electr Bike

LED lighting: Yes

rated power: 7w

Output Voltage/Current:220V/32A: Input Voltage/Current:220v/32a

Applicable Scenes:

They are suitable for occasions such as private villas, residential areas, commercial office buildingsurban complex parking lots or urban public charging stations that can charge slowlyforalong time;or applied for 4S stores of new energy vehicles, workshop debuggingareas,road rescue of new energy vehicles and other occasions that require frequent change of Charging Station sites or temporary power supply.



Features;
Delicate appearance,simple operation,convenient installation;

High efficiency, reliable and stable performance;

Friendly interaction interface,4.3-inch color touch screen;
Support multiple modes of charging,operation management and payment;
Support Ethernet or wireless telecommunication;
Support RFID Card/OCPP1.6(optional);
Support Type-2connector(or Socket)optional; Overloadintegrated Protection;
Supportonline data upgrade.


Technical Date

S. NO.

Parameters

Requirements

General Requirements

1

Ev Charger Type

AC

2

Charger Capacity

7KW(Plug and play)

7KW

11KW

3

Model No.

ENC-ACL007A /

ENC-ACB007A

ENC-ACL007A /

ENC-ACB007A

ENC-ACL011A /

ENC-ACB011A

4

Mounting

Column type/ Wall-mounted

Input Requirements

5

AC Supply System

Single-Phase, 3 Wire AC system

Three-Phase, 5 Wire AC

system

6

Nominal Input voltage

220V ± 15%

380V ± 15%

7

Input frequency

50Hz, ±1.5Hz / 60Hz, ±1.5Hz

Environmental Requirements

8

Ambient Temperature Range

-25 to 55°C

9

Ambient Humidity

5 to 95%

10

Storage temperature

-40 to 70°C

Mechanical Requirements

11

IP Ratings

IP 54

12

Cooling

Air cooled

Output Requirements

13

Number of outputs

1

14

Type of each output

220V ± 15% single phase, 32Amp

380V ± 15% three phase,

16Amp

15

Output Current

32 Amp

16 Amp

16

Output Connector

Compatibility

IEC-61851-22, IEC 62196-2 Mode 2, Type 2

User Interface & Display Requirements

17

Display & touch-screen size

/

4.3 inches

4.3 inches

18

User Authentication

Mobile application or User interface / QR Code/RFID Card /Password Login

19

Metering Information

Consumption Units

Communication Requirements

20

Communication between

EVSE and Central Server

/

OCPP 1.6 protocol

(optional)

OCPP 1.6 protocol

(optional)

21

Interface between charger

and CMS

Ethernet and GPRS Modem

Protection & Safety Requirements

22

Safety Parameters

Over current, under voltage, Residual current, Surge protection, leakage

protection, Short circuit, Over temperature, etc.

23

Power failure

If there is a power failure, user is indicated about this.