Model No.: ENC-ACL007A
place of origin: China
Types of: Wall Charger, Charging Stand
Certification: Weee, Ul, Sig(bluetoothsig), Sgs, Rohs, Rech, Gs, Fcc, Csa, Ce, Bis(isi)
use: Electric Car, Electr Bike
LED lighting: Yes
rated power: 7w
Output Voltage/Current:220V/32A: Input Voltage/Current:220v/32a
Applicable Scenes:
They are suitable for occasions such as private villas, residential areas, commercial office buildingsurban complex parking lots or urban public charging stations that can charge slowlyforalong time;or applied for 4S stores of new energy vehicles, workshop debuggingareas,road rescue of new energy vehicles and other occasions that require frequent change of Charging Station sites or temporary power supply.
Features;
Delicate appearance,simple operation,convenient installation;
High efficiency, reliable and stable performance;
Friendly interaction interface,4.3-inch color touch screen;
Support multiple modes of charging,operation management and payment;
Support Ethernet or wireless telecommunication;
Support RFID Card/OCPP1.6(optional);
Support Type-2connector(or Socket)optional; Overloadintegrated Protection;
Supportonline data upgrade.
Technical Date
S. NO. |
Parameters |
Requirements |
||
General Requirements |
||||
1 |
Ev Charger Type |
AC |
||
2 |
Charger Capacity |
7KW(Plug and play) |
7KW |
11KW |
3 |
Model No. |
ENC-ACL007A / ENC-ACB007A |
ENC-ACL007A / ENC-ACB007A |
ENC-ACL011A / ENC-ACB011A |
4 |
Mounting |
Column type/ Wall-mounted |
||
Input Requirements |
||||
5 |
AC Supply System |
Single-Phase, 3 Wire AC system |
Three-Phase, 5 Wire AC system |
|
6 |
Nominal Input voltage |
220V ± 15% |
380V ± 15% |
|
7 |
Input frequency |
50Hz, ±1.5Hz / 60Hz, ±1.5Hz |
||
Environmental Requirements |
||||
8 |
Ambient Temperature Range |
-25 to 55°C |
||
9 |
Ambient Humidity |
5 to 95% |
||
10 |
Storage temperature |
-40 to 70°C |
||
Mechanical Requirements |
||||
11 |
IP Ratings |
IP 54 |
||
12 |
Cooling |
Air cooled |
||
Output Requirements |
||||
13 |
Number of outputs |
1 |
||
14 |
Type of each output |
220V ± 15% single phase, 32Amp |
380V ± 15% three phase, 16Amp |
|
15 |
Output Current |
32 Amp |
16 Amp |
|
16 |
Output Connector Compatibility |
IEC-61851-22, IEC 62196-2 Mode 2, Type 2 |
||
User Interface & Display Requirements |
||||
17 |
Display & touch-screen size |
/ |
4.3 inches |
4.3 inches |
18 |
User Authentication |
Mobile application or User interface / QR Code/RFID Card /Password Login |
||
19 |
Metering Information |
Consumption Units |
||
Communication Requirements |
||||
20 |
Communication between EVSE and Central Server |
/ |
OCPP 1.6 protocol (optional) |
OCPP 1.6 protocol (optional) |
21 |
Interface between charger and CMS |
Ethernet and GPRS Modem |
||
Protection & Safety Requirements |
||||
22 |
Safety Parameters |
Over current, under voltage, Residual current, Surge protection, leakage protection, Short circuit, Over temperature, etc. |
||
23 |
Power failure |
If there is a power failure, user is indicated about this. |